YAG 600W optical fiber transmission energy negative feedback laser welding equipment
Product Description |
Energy negative feedback control refers to comparing the desired output laser energy waveform with the actual output energy waveform in real time to determine the input power of the pump lamp. The system automatically controls the input power of the pump lamp to be consistent each time, thereby controlling A consistent way to output energy. |
Features |
1. It has a negative energy feedback function to ensure that the electric power of the xenon lamp is stable and consistent each time and the output energy has small fluctuations; 2. Support arbitrary waveform settings, so that each material has the most suitable waveform parameters; 3. The peak power can reach up to 10KW and has good penetration power; |
|
4. The single-point energy can reach up to 100J, which can be used for welding high-reflective materials such as copper, aluminum, gold, and silver; 5. Optical fiber transmission structure, flexible and simple to match with automation equipment; 6. Modular structural design makes maintenance simple and easy; 7. Support multiple language switching, such as Simplified Chinese, Traditional Chinese, English, Korean, Vietnamese, etc. |
Parameters |
Laser wavelength | 1064nm |
Maximum output optical power | 600W |
Maximum pulse energy | 100J |
Maximum peak power | 10KW |
pulse width | 0.1-20ms |
pulse repetition frequency | 1~200HZ |
Welding penetration (stainless steel) | 3.0mm |
Welding penetration (carbon steel plate) | 3.0mm |
Welding penetration (pure aluminum) | 2.0mm |
Welding penetration (red copper) | 2.0mm |
Welding penetration (brass) | 2.0mm |
Spectral method | Precision energy spectroscopy or high-speed time spectroscopy |
Closed loop feedback control method*** | Arbitrary waveform real-time control of energy negative feedback |
energy volatility*** | <±3%*** |
fiber optic coupling system | With water cooling option, with optical fiber in place alarm function (optional) |
Number of optical fiber splitting channels | <6 (standard single optical path) |
Aiming and positioning methods | Laser diode red light indication (CCD optional) |
cooling method | External chiller (external circulating water flow alarm) |
Device power consumption | 22KW |
Power requirements | AC380V±10% 50/60Hz |
Internal circulation performance*** | With water level, water temperature, water flow rate. Water conductivity alarm function |
internal circulatory system | Epoxy resin filtration (standard water pump 50HZ, customized 60HZ depending on the area) |
Host size | 1460*660*1080mm (length*width*height) |
Sample Display |